ONLINE RELAY COORDINATION STUDY

(TCC Curves & Protection Coordination)

Over Current & Earth Fault Coordination • MCCB/Fuse Char. Curves • Fault Impedance • Motor Start & Base Load Curve

Unified Workspace

Everything Available on One Screen

Settings, interactive curves, equipment hierarchy and alarms remain visible together, helping engineers make faster and better-informed protection decisions.

↻

Live Parameter Updates

Changes in relay settings are reflected directly on the chart and Single Line Diagram.

▦

Integrated Engineering View

Settings, curves, system hierarchy and alarm results stay visible together.

∆t

Faster Coordination Review

Compare upstream and downstream devices without repeatedly changing pages.

⎍

Clear System Context

Relate each protection curve to its physical position in the electrical network.

Simple Configuration

Structured Relay and System Settings

Configure the study without complicated navigation. Related parameters remain grouped in clean, readable panels.

All Major Parameters in a Simple Format

A clear, single-page interface provides complete Over Current and Earth Fault configuration. Enter CT ratios, IDMT curve families, plug settings, TMS values and multiple definite-time stages while retaining direct access to system-wide settings.

  • Phase and earth-fault CT ratios
  • IDMT curve family and plug setting
  • TMS or operating delay
  • DT Stage 1 and DT Stage 2
  • Relay insertion, naming and enable controls
  • Current range, time margin and study mode
  • Source fault level and current capping
  • Busbar, transformer, cable, fuse and MCCB modules
Interactive Protection Curves

Interactive Time–Current Curves

Precisely compare relay characteristics on a log–log chart and evaluate selectivity across the complete operating-current range.

Fast Visual Coordination

Users can isolate individual relays, display additional equipment curves, float the chart and drag curves for rapid setting evaluation.

Individual relay selectionAll-relay displayOver Current modeEarth Fault modeAdjustable current rangeAdjustable time rangeClear alarmsFloat chartDrag curvesFault-zone selection
X-axis: Current in amperes Y-axis: Operating time in seconds
Network Visualization

Dynamic Single Line Diagram

The dynamic Single Line Diagram visualises the protection network from source to load and keeps each curve connected to its actual electrical-system position.

  • Source-to-load hierarchy
  • Relay and equipment identification
  • Transformer ratio and impedance
  • Primary and secondary grounding
  • Fault-current display
  • Operating-time display
  • Running and peak voltage
  • Fault-location indication
Built-In Validation

Advanced Protection Alarm Intelligence

The platform automatically identifies protection risks and presents clear engineering warnings directly beneath the chart.

Minimum Time Margin

Detects coordination margins below the configured minimum value.

Reverse Coordination

Identifies an upstream device operating before downstream protection.

Curve Crossing

Highlights overlapping or intersecting protection characteristics.

Pickup Below Load

Warns when relay pickup is below the calculated maximum load current.

Motor Starting

Detects a relay that may operate during acceleration or re-acceleration.

Transformer Inrush

Compares relay trip time with transformer inrush duration.

Fuse & MCCB Selectivity

Checks coordination with downstream protective devices.

Fault-Zone Logic

Evaluates devices expected to respond in the selected network zone.

Earth-Fault Blocking

Recognises grounding or transformer configurations that block fault transfer.

Equipment Condition

Highlights through-fault or loading conditions requiring review.

Multi-Device Coordination

Fuse and MCCB Curves in One Click

Display fuse and MCCB curves instantly alongside relay characteristics. Compare operating times, intersections and coordination margins without switching between separate screens.

  • Relay-to-fuse coordination
  • Relay-to-MCCB coordination
  • One-click curve visibility
  • Equipment position linked to the SLD
  • Local operating-current evaluation
  • Coordination alarm support
Energisation Stability

Transformer Inrush Stability Check

Transformer inrush-current plotting verifies relay stability during energisation and raises an alarm when protection settings may cause unwanted operation.

Inrush Comparison

Compare relay operating time with transformer inrush current and duration.

Unsafe-Setting Alarm

Identify pickup, TMS or delay values that require correction.

Transformer FLCInrush multiplierInrush durationRelay operating timeMinimum marginVisual TCC check
Advanced Fault Simulation

Zone-Wise Earth-Fault Simulation

Evaluate earth-fault protection behaviour across multiple electrical-network sections with synchronized TCC and Single Line Diagram views.

Zone-1Downstream or low-voltage fault section
Zone-2Intermediate transformer or distribution section
Zone-3Upstream network and source-side section
Automatic zone mappingVector-group considerationNGR and grounding behaviourFault-current cappingActive or blocked relaysNo-Trip indicationZone-specific curvesFault voltage comparison
Print-Ready Documentation

Professional Engineering Reports

Generate structured reports for protection-setting review, coordination verification, calculations, approval and final project documentation.

Print-ready · Settings

All Settings Report

Consolidates basic parameters, transformer, busbar, cable, fuse and MCCB information and displays the total number of alarming conditions.

Print-ready · Coordination

Chart & Single Line Diagram

Presents the TCC chart, relay-setting summary and complete Single Line Diagram on one professional page.

Print-ready · Coordination

Relay Coordination Report

Compares relay operating times and coordination margins at multiple fault-current levels with colour-coded results.

Print-ready · Calculation

Fault-Voltage Calculation

Shows upstream source, transformer and cable impedance contributions, exact formulas, voltage drop and resulting fault voltage.

Print-ready · Calculation

Fault-Current Calculation

Presents source, transformer and cable impedance, total equivalent impedance and calculated three-phase short-circuit current.

Print-ready · Calculation

Running & Peak Voltage

Evaluates running-load and peak or motor-starting voltage using load current, motor-start current, power factor and impedance.

Project Continuity

Secure Cloud-Based Project Storage

Account-based cloud storage allows users to upload, search, load, download and delete study files from a compatible device, supporting project backup, recovery and continuation.

Upload StudySearch FilesLoad into ToolDownload BackupDelete FileSigned-In AccessCross-Device Continuation
Engineering Data Output

One-Click Printable Settings Export

Convert complete Over Current and Earth Fault relay settings into a structured Excel workbook for review, approval and sharing.

Complete Protection Settings in a Professional Format

The organised workbook includes protection device details, CT ratios, stage settings, curve families, pickup values, time delays and engineering remarks.

  • Protection device ID
  • Relay model and make
  • Phase CT ratio
  • Earth-fault CT ratio
  • Stage 1 settings
  • Stage 2 settings
  • Stage 3 settings
  • Curve family
  • Pickup current
  • TMS or delay
  • Directional information
  • Disabled-relay remarks
Explore Export & Reports
Transparent Results

Engineering Calculations You Can Review

Calculation reports present formulas, intermediate values and referenced impedances so results can be independently checked.

01

Source Impedance

Calculate source reactance from fault level and nominal voltage.

02

Transformer Impedance

Refer transformer impedance across voltage stages.

03

Cable R & X

Include cable resistance, reactance, length and parallel runs.

04

Fault Current

Calculate three-phase short-circuit current at the selected stage.

05

Fault Voltage

Evaluate voltage remaining at the faulted node.

06

Running Voltage

Determine running-load voltage and percentage drop.

07

Peak Voltage

Evaluate motor-start or peak-load voltage performance.

08

Zone Capping

Apply stage-specific through-fault current limits.

Designed for Protection Studies

Why Use RelayCoordination.com?

01

Complete Protection Study

OC, EF, relay, fuse, MCCB, transformer and motor-start evaluation.

02

Visual Engineering

Interactive curves and a dynamic Single Line Diagram remain synchronised.

03

Intelligent Validation

Automatic alarms identify inadequate settings and coordination problems.

04

Zone-Based Simulation

Study fault behaviour across multiple electrical-network sections.

05

Transparent Calculations

Detailed formulas and intermediate values support independent checking.

06

Professional Documentation

Generate printable charts, reports and structured settings sheets.

07

Cloud Project Handling

Save and continue studies through account-based online storage.

08

One-Click Export

Export complete protection settings into a printable Excel format.

From System Data to Final Report

Complete Study Workflow

  1. 1Create or upload a project
  2. 2Configure source and system data
  3. 3Add transformers, cables and devices
  4. 4Enter OC and EF settings
  5. 5Plot and compare TCC curves
  6. 6Run fault and voltage simulations
  7. 7Review alarms, reports and exports
Start Your Study

Start Your Relay Coordination Study Online

Develop protection settings, compare TCC curves, simulate faults, verify voltage performance and generate engineering reports from one integrated platform.

Use the study mode appropriate to your system complexity and engineering requirements.
Contact & Support

Questions About the Relay Coordination Tool?

For technical queries, use this contact form or email relay.coord@gmail.com.

RelayCoordination.com Online relay coordination and protection engineering platform.