Live Parameter Updates
Changes in relay settings are reflected directly on the chart and Single Line Diagram.
(TCC Curves & Protection Coordination)
Over Current & Earth Fault Coordination • MCCB/Fuse Char. Curves • Fault Impedance • Motor Start & Base Load Curve
Settings, interactive curves, equipment hierarchy and alarms remain visible together, helping engineers make faster and better-informed protection decisions.
Changes in relay settings are reflected directly on the chart and Single Line Diagram.
Settings, curves, system hierarchy and alarm results stay visible together.
Compare upstream and downstream devices without repeatedly changing pages.
Relate each protection curve to its physical position in the electrical network.
Configure the study without complicated navigation. Related parameters remain grouped in clean, readable panels.
A clear, single-page interface provides complete Over Current and Earth Fault configuration. Enter CT ratios, IDMT curve families, plug settings, TMS values and multiple definite-time stages while retaining direct access to system-wide settings.
Precisely compare relay characteristics on a log–log chart and evaluate selectivity across the complete operating-current range.
Users can isolate individual relays, display additional equipment curves, float the chart and drag curves for rapid setting evaluation.
The dynamic Single Line Diagram visualises the protection network from source to load and keeps each curve connected to its actual electrical-system position.
The platform automatically identifies protection risks and presents clear engineering warnings directly beneath the chart.
Detects coordination margins below the configured minimum value.
Identifies an upstream device operating before downstream protection.
Highlights overlapping or intersecting protection characteristics.
Warns when relay pickup is below the calculated maximum load current.
Detects a relay that may operate during acceleration or re-acceleration.
Compares relay trip time with transformer inrush duration.
Checks coordination with downstream protective devices.
Evaluates devices expected to respond in the selected network zone.
Recognises grounding or transformer configurations that block fault transfer.
Highlights through-fault or loading conditions requiring review.
Display fuse and MCCB curves instantly alongside relay characteristics. Compare operating times, intersections and coordination margins without switching between separate screens.
Transformer inrush-current plotting verifies relay stability during energisation and raises an alarm when protection settings may cause unwanted operation.
Compare relay operating time with transformer inrush current and duration.
Identify pickup, TMS or delay values that require correction.
Evaluate earth-fault protection behaviour across multiple electrical-network sections with synchronized TCC and Single Line Diagram views.
Generate structured reports for protection-setting review, coordination verification, calculations, approval and final project documentation.
Consolidates basic parameters, transformer, busbar, cable, fuse and MCCB information and displays the total number of alarming conditions.
Presents the TCC chart, relay-setting summary and complete Single Line Diagram on one professional page.
Compares relay operating times and coordination margins at multiple fault-current levels with colour-coded results.
Shows upstream source, transformer and cable impedance contributions, exact formulas, voltage drop and resulting fault voltage.
Presents source, transformer and cable impedance, total equivalent impedance and calculated three-phase short-circuit current.
Evaluates running-load and peak or motor-starting voltage using load current, motor-start current, power factor and impedance.
Account-based cloud storage allows users to upload, search, load, download and delete study files from a compatible device, supporting project backup, recovery and continuation.
Convert complete Over Current and Earth Fault relay settings into a structured Excel workbook for review, approval and sharing.
The organised workbook includes protection device details, CT ratios, stage settings, curve families, pickup values, time delays and engineering remarks.
Calculation reports present formulas, intermediate values and referenced impedances so results can be independently checked.
Calculate source reactance from fault level and nominal voltage.
Refer transformer impedance across voltage stages.
Include cable resistance, reactance, length and parallel runs.
Calculate three-phase short-circuit current at the selected stage.
Evaluate voltage remaining at the faulted node.
Determine running-load voltage and percentage drop.
Evaluate motor-start or peak-load voltage performance.
Apply stage-specific through-fault current limits.
OC, EF, relay, fuse, MCCB, transformer and motor-start evaluation.
Interactive curves and a dynamic Single Line Diagram remain synchronised.
Automatic alarms identify inadequate settings and coordination problems.
Study fault behaviour across multiple electrical-network sections.
Detailed formulas and intermediate values support independent checking.
Generate printable charts, reports and structured settings sheets.
Save and continue studies through account-based online storage.
Export complete protection settings into a printable Excel format.
Develop protection settings, compare TCC curves, simulate faults, verify voltage performance and generate engineering reports from one integrated platform.
Use the study mode appropriate to your system complexity and engineering requirements.For technical queries, use this contact form or email relay.coord@gmail.com.